Filter Results By:

Products

Applications

Manufacturers

Power Sources

Supply stable and consistant electrical or light energy.


Showing results: 916 - 930 of 974 items found.

  • SpikeSafe DC / Continuous Pulsed Current Sources

    Vektrex Electronic Systems

    The Vektrex SpikeSafe™ DC / Continuous Pulse (DCP) Current Sources provide reliable DC or pulsed drive for LED or laser diode reliability testing, IESNA LM-80 maintenance testing, and other test applications requiring DC or continuous pulse current. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, accurate pulsing over long output cables, precise current, precision pulsing for improved measurement repeatability, and high power density — typically 6.4kW-8kW.

  • Load Cell Power Supply

    MODEL PSMR - Transducer Techniques, Inc

    The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.

  • Level System

    Universal II - AMETEK Drexelbrook

    The Universal II level transmitter offers increased reliability, low maintenance and an intrinsically safe design for dependable level measurements in all kinds of process liquids, slurries, granulars and interfaces.Universal IIThe Universal II is a two wire level transmitter that eliminates the need for line power in the field and saves costs for additional hardware. It provides reliable level measurements in all kinds of process liquids, slurries, granulars and interfaces.When powered from an approved source this level transmitter can be made intrinsically safe. Its rugged contruction resists corrosion and abraision. The no moving parts design eliminates break downs.The Universal II level transmitter utilizes RF Admittance technology with manual calibration and a 4 – 20 mA output signal. The patented Cote-Shield circuitry ensures accuracy and reliability regardless of product build-up on the level transmitter.This level system is unaffected by changes in the process material density, pressure, or temperature variations.

  • Solenoid-Saver

    B-1022-B - ROSS ENGINEERING CORPORATION

    *Solenoid-Saver® eliminates AC hum and reduces heat generation for many types of solenoids.*Controlled application of current prevents coil burnout if high pull-in/low holding current AC or DC solenoids fail to pull-in completely.*Can adapt high pull-in low holding current solenoids to special voltages & frequencies 12V to 250V DC or 12V to 240V AC wideband 25-800Hz.*Optional optical isolated control input 4 to 10V, 5MA, 20 usec or more (or other control voltages) to actuate any high current solenoid directly by computer or other low power signal source.*For coils of 1 ohm to 3,500 ohms DC resistance requiring up to 70 amps during pull-in up to 120 milliseconds. Basic solenoid coil voltage and resistance must be specified.*Eliminates heat producing dropping resistors, bypass switch, dual coils, laminations, & shading coils.*Can increase pull-in and holding force of many types of solenoids.*Optional stored energy to delay solenoid release on loss of power.*Can be used as an added accessory to existing solenoid installation to eliminate AC hum, lower coil temperature and prevent coil burnout.*Optional high speed, 1 microsecond sensing, 1-10 millisecond actuation with stored energy Solenoid-Saver®

  • AC Hipot Tester /DC Hipot Tester

    YD-Series - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    YD series HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high voltage. The insulation test result of the tester is go or not go. Also the YD series HIPOT tester is a universal power source in HV test. The maximum output voltage and capacity could be customized according the requirements of custom.The tester is consists of single HV transformer and main control box. There are two kinds of HV transformer according to the insulation materials of the HV transformer.They are dry HV transformer and oil HV transformer. For the dry HV transformer the insulation material is epoxy resin.For oil HV transformer the insulation material is insulation oil. The dry HV transformer has a smaller size and less weight than oil HV transformer. But the maximum output voltage is less than 100kv for dry HV transformer. The functions of the main control box are voltage output regulation, protection in emergency and voltage/current value indication

  • Tunable, Ultrafast TI: Sapphire Laser

    SPRITE XT - M Squared Lasers

    Sprite XT is a flexible ultrafast, femtosecond laser source. It delivers stability, reliability and productivity and is equally at home in the lab or as part of an OEM application. Choose your output power (up to multi-Watts), pulse width (femtosecond or picosecond models), wavelength range (fixed wavelength or tunable), and pulse repetition rate (<80 MHz to multi-GHz). All Sprite models are designed for alignment-free and maintenance-free operation and can be controlled from a web browser. It’s ideal for multi-photon excitation (MPE) and FLIM, quantum optics, time resolved spectroscopy, nonlinear optics, pump-probe experiments, microscopy, amplifier seeding, and electro-optic sampling.

  • NI-9231, 8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module

    783610-01 - NI

    8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module - The NI-9231 is a high-density sound and vibration module that can measure signals from integrated electronic piezoelectric (IEPE) and non-IEPE sensors such as accelerometers, tachometers, and proximity probes. It can perform the high dynamic range measurements necessary for modern measurement microphones and accelerometers and features simultaneous sampling. The NI-9231 incorporates both a TEDS input path and 2 mA of IEPE signal excitation source that can be turned on and off, removing the need for external sensor power and reducing the complexity of the data acquisition system.

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • Single Channel USB Programmable Band-Pass Filter

    USBPBP-S1 - Alligator Technologies

    The USBPBP-S1 stand alone USB controllable module provides a single channel of high and low-pass filtering and high-quality instrumentation amplifier for front-end signal conditioning compatible with all popular A/D converter devices. The USBPBP-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPBP-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPBP-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.

  • Single Channel USB Programmable Instrumentation Amplifier

    USBPIA-S1 - Alligator Technologies

    The USBPIA-S1 stand alone USB controllable module provides a single channel of high-quality instrumentation amplifier and optional AC coupling, for front-end signal conditioning compatible with all popular A/D converter devices. The USBPIA-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPIA-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPIA-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.

  • Single Channel USB Programmable High-Pass Filter

    USBPHP-S1 - Alligator Technologies

    The USBPHP-S1 stand alone USB controllable module provides a single channel of high pass filtering and high-quality instrumentation amplifier for front-end signal conditioning compatible with all popular A/D converter devices. The USBPHP-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPHP-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPHP-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.

  • Manual Oscillators

    MOS-01, -01A - Compact Power Company

    The MOS-01 manual oscillator module is used as a quality, general-purpose sinewave oscillator and digital readout monitoring system in the MAC-01, -02, or -03 AC Power Sources/Frequency Converters. The unit has guaranteed operating range of 20 HZ to 20 KHZ which is covered in three one-decade scales. The LCD digital metering system is switch-selectable to readout either frequency, voltage or current. A toggle switch selects the input for the attached AC Power Source/Frequency Converter to originate from the manual oscillator itself or from an external laboratory or programmable oscillator source. With oscillator mode switch in Internal position, the BNC connector delivers the signal to drive additional slave units or for oscilloscope sync or monitoring. BNC input/output is completely isolated with 1500 VAC breakdown and excellent common mode rejection. The oscillator modules must be factory installed and calibrated.

  • Multifunction Calibrator 15 ppm Basic Accuracy

    MC142 - Powertek LLC

    Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.

  • Pressure Calibrators

    Fluke Calibration

    Wherever you need to work and whatever pressure range you need to work with, our broad selection of tools will meet your needs. From pneumatic or hydraulic deadweight testers and test pumps to electronic deadweight testers, bench controllers, and precise analog pressure gauges, we have you covered at the bench. Going into the field? Fluke’s portable pressure calibrators – with or without pumps and intrinsically safe or not – work with gases or liquids, source and measure, power transmitters, and cover a wide range. With individually available pressure modules, our portable and bench solutions cover pressures from vacuum to 10,000 psi.

  • Adjustable High Frequency Reference Ballast

    HCS-109A - Lisun Electronics Inc.

    HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)

Get Help